<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>International Journal of Optimization in Civil Engineering</title>
<title_fa>عنوان نشریه</title_fa>
<short_title>IJOCE</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ijoce.iust.ac.ir</web_url>
<journal_hbi_system_id>18</journal_hbi_system_id>
<journal_hbi_system_user>agent2</journal_hbi_system_user>
<journal_id_issn>2228-7558</journal_id_issn>
<journal_id_issn_online>3060-8236</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>doi</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>OPTIMUM RESISTANCE FACTOR FOR REINFORCED CONCRETE BEAMS RETROFITTED WITH U-WRAP FRP</title>
	<subject_fa>Optimal design</subject_fa>
	<subject>Optimal design</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>The  use  of  fiber  reinforced  polymer  (FRP)  U-wrap  to  rehabilitate  concrete  beams  has increased in popularity over the past few years. As such, many design codes and guidelines have been developed to enable designers to use of FRP for retrofitting reinforced concrete beams. FIB is the only guideline for design which presents a formula for torsional capacity of  concrete  beams  strengthened  with  FRP.  The  Rackwitz-Fiessler  method  was  applied  to make a reliability assessment on the torsional capacity design of concrete beams retrofitted with U-wrap FRP laminate by this guideline. In this paper, the average of reliability index obtained is 2.92, reflecting reliability of the design procedures. This value is somehow low in  comparison  to  target  reliability  level  of  3.5  used  in  the  guideline  calibration  and  so, optimum resistance factor may be needed in future guideline revisions. From the study on the  relation  between  average  reliability  index  and  optimum  resistance  factor,  a  value  of 0.723 for the optimum resistance factor is suggested.</abstract>
	<keyword_fa></keyword_fa>
	<keyword>fiber  reinforced  polymer,  reliability  analysis,  optimum  resistance  factor,  torsion retrofitting, concrete beams.</keyword>
	<start_page>227</start_page>
	<end_page>240</end_page>
	<web_url>http://ijoce.iust.ac.ir/browse.php?a_code=A-10-66-64&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>H.</first_name>
	<middle_name></middle_name>
	<last_name>Dehghani </last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>18003194753284600822</code>
	<orcid>18003194753284600822</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M. J.</first_name>
	<middle_name></middle_name>
	<last_name>Fadaee</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>18003194753284600823</code>
	<orcid>18003194753284600823</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
